16 Port Serial Server
B094-008-2E-M-F 8port Console Server with dual NIC and Modem; 2 x Cat5 Blue Patch Cable; DB9F-RJ45 Adapter: 1 Straight pinned and 1 Crossed; External Power Supply.
Supports RS-232/422/485 serial communication; Provides 10/100 Mbps auto-sensing Ethernet port; Supports baud rate up to 921.6 kbps; Provides COM port redirection.
The RSM-16 Remote Site Manager provides secure, in-band and out-of-band access to RS232 console ports and maintenance ports on UNIX servers, routers and any other.
The 4104 Ethernet to serial server is the easiest way to connect RS-232, RS-422, or RS-485 serial devices to your Ethernet network. SeaLINK products use industry.
The uPCI 16-Port RS-232/422 is separate, panel-mountable interface. RocketPort multi port serial card from COMTROL has 16 RS-232/422 DB25F connections.
This RocketPort universal PCI 16-Port serial card is compatible with all current 3.3 and 5.0 Volt PCI bus architectures
Part Number: 99355-1
RoHS 2 compliant under CE
Universal PCI design supporting 3.3 and 5.0 Volt PCI bus architectures – ensures compatibility with all current PCI bus architectures
I/O mapping capabilities – simplifies installation, eliminates memory conflicts, and enables plug-and-play compatibility
16-port serial expansion utilizing a single PCI slot – delivers large scale serial port expansion
Standard IT rackmount RJ45 and surge protected DB25 interfaces available – provides compatibility with existing rack mount equipment and harsh environments
On-board dedicated 36MHz RISC processor – minimizes host CPU utilization
Support for RS-232 and RS-422 interfaces on each port – provides more options and enhanced compatibility
Transmit buffers 16 times larger, and receive buffers 64 times larger than a 16550 UART – helps ensure smooth, efficient data transfer
Robust driver support – enables card to work seamlessly with popular operating systems
The RocketPort uPCI 16-Port serial expansion card is compatible with all current 3.3 and 5.0 Volt PCI bus architectures. It provides 16 native serial ports utilizing a single PCI card slot and an external serial interface module available sold separately that supports RS-232 or RS-422 serial communications at speeds up to 230 Kbps. Individual serial ports on the same interface module can be configured for either RS-232 or RS-422 communication. External interface modules with additional surge protection are also available.
RocketPort products are designed with larger transmit-and-receive buffers than those of a 16550 UART found in typical PC serial ports and low-end serial cards, enabling them to handle the transmission of large amounts of data reliably and efficiently. They also utilize an on-board 36MHz processor, minimizing host CPU utilization. RocketPort products do not require the assignment of interrupts, simplifying installation and eliminating conflicts with other server cards. Drivers are available for popular operating systems. The product is fully compliant with the RoHS 2 directive under CE.
Includes:
RocketPort uPCI 16 Port Device
Interface Cable
Comtrol Software Documentation CD.
SSH Console Switch delivers secure management of serial devices via the internet, TCP/IP network or dial-up modem. Controls up to 32 network devices.
Console Serial Port Switch provides remote nework management via RS232 serial ports. Control up to 32 network devices servers, routers, network switches via serial.
Aug 22, 2012 In this Coffee Coaching video, Andy Brown, an architect on the HP iLO Firmware team, demonstrates some of the capabilities of iLO4 when integrating into a.
Also known as: console switch, serial port switches, RS232 switch, serial switch box, UNIX SUN workstation switch,
sun switch, console switcher, serial port sharing switch, network server management solution.
SERIMUX-CS-32E Front Back
Additional Images
The SERIMUX Console Switch gives IT managers the ability to cost effectively manage serial devices, including servers, switches, routers, and telecom gear. The switch can be controlled via an ASCII terminal with menu-driven integrated software, the front panel keypad, or optional Ethernet interface.
The SERIMUX Console Switch gives IT managers the ability to cost effectively manage serial devices, including servers, switches, routers, and telecom gear. The switch can be controlled via an ASCII terminal with menu-driven integrated software, the front panel keypad, or optional Ethernet interface.
Eliminates the need to connect each device to an ASCII terminal or PC.
Connect up to 32 devices with different baud rates, parity, and character length. Each switch also has one RJ45 connector for a local terminal.
Provides out-of-band access to network devices servers, routers, network switches, and any other network devices allowing console operation using RS232.
Power cycle without halting SUN host computer.
No inadvertent break signals are generated to cause unintentional rebooting of SUN computers.
Dual power option creates a redundant power system protecting the console switch from any power failure issues.
High quality, rugged steel construction with durable powder coat finish.
Command Line Interface via Telnet for advanced management functions.
Connects to console serial ports using standard CAT5/5e/6 cables and cable adapters.
Maximum cable length is 100 feet 30 meters.
Two operator levels administrator and user.
Switching is simplified with programmable device names and menu-driven device selection.
All configuration parameters are stored in non-volatile EEPROM.
Built-in data buffers save the most recent RS232 console output from each connected device, which simplifies troubleshooting failures.
Local commands can be directed via VT52, VT100, ANSI serial console, a PC with a terminal emulation program, or any compliant terminal.
Gain access to servers without interrupting service to end-users; maintain optimal up-time.
Manage server farms or data centers via serial ports and standard external modems or through optional Ethernet interface using Telnet or Web interface.
1RU rackmount case is standard.
Compatibility
Supports most devices with an RS232 serial port.
Serial Interface
4, 8, 16, 24 or 32 RJ45 EIA-232 serial port connectors.
One RJ45 EIA-232 console port connector.
Flow control: Hardware RTS/CTS, Software XON, XOFF, both or none.
Signals: TXD, RXD, DSR, DTR, CTS, RTS, DCD
Data transfer rate: up to 115.2K baud between two ports.
Two ports can be at different baud rates.
Network Interface Optional
10/100 BaseT Ethernet port with RJ45 connector.
Supports static and dynamic IP addresses.
Power
Input Voltage: AC 100 - 240V, 50 - 60 Hz
Optional dual power available on all models.
Power Consumption
Model
Power W
4-port
5
24-port
10
8-port
32-port
16-port
Adapters
Four cable adapters are included with the SERIMUX.
DB-25F to RJ45 console adapter.
DB-9F to RJ45 console adapter.
DB-25M to RJ45 console adapter.
DB-25M to RJ45 modem adapter.
Additonal
adapters available.
Adapter
pinout diagrams.
Protocols For Optional Ethernet Control
HTTP, HTTPS, ICMP, DHCP.
TCP/IP, SSL, Telnet.
Environmental
Operating temperature: 32 - 100 F 0 - 38 C.
Storage temperature: -20 - 140 F -30 - 60 C.
Operating and Storage Relative Humidity: 17 - 90 non-condensing RH.
Regulatory Approvals
Warranty
MTBF
NTI Part
MTBF hrs
SERIMUX-CS-4
57,847
SERIMUX-CS-4E
50,793
SERIMUX-CS-4DP
57,695
SERIMUX-CS-4EDP
50,661
SERIMUX-CS-8
54,652
SERIMUX-CS-8E
48,506
SERIMUX-CS-8DP
54,526
SERIMUX-CS-8EDP
48,406
SERIMUX-CS-16
53,238
SERIMUX-CS-16E
47,383
SERIMUX-CS-16DP
53,107
SERIMUX-CS-16EDP
47,280
SERIMUX-CS-24
50,304
SERIMUX-CS-24E
45,045
SERIMUX-CS-24DP
50,198
SERIMUX-CS-24EDP
44,959
SERIMUX-CS-32
48,240
SERIMUX-CS-32E
43,383
SERIMUX-CS-32DP
48,143
SERIMUX-CS-32EDP
43,304
Dimensions
Console Serial Port Switches without supplied rackmount kit
Desktop Size
WxDxH in.
9x6x1.75
11x6x1.75
15.3x6x1.75
16.2x6x1.75
Front panel keypad.
Secured by a user-defined numeric password.
Menu-driven integrated software via serial terminal console.
Command Line Interface
Remote administration and maintenance of the SERIMUX Console Serial Port Switch.
Execute frequently performed configuration tasks through script files.
Save the configuration of the switch, and perform configuration restoration if needed.
Restore default configuration parameters to specific parts of the switch, while leaving other custom configuration parameters intact.
Administrative Controls
View and/or modify port parameters.
View and/or modify user passwords and parameters.
Restore default configuration parameters.
Connect or disconnect port connections.
Change/disconnect users, administrators, passwords, etc.
Initiate modem connection to local ports.
Inspect buffered data.
View/delete port-buffer data-log contents.
User passwords become invisible while viewing the buffers.
Application Drawings
Console Serial Port Switch with Ethernet Control Option
How to manage up to 32 IT devices - routers, switches, hubs, etc.
Application Notes
Dual Redundant Secure Access to Serial Ports
To gain dual redundant secure access to the serial ports of servers, begin by connecting a server to the console port of the SERIMUX-CS-xx. Then, configure a serial port on the SERIMUX-CS-xx to a user port and connect an additional server to that port. Use Secure Shell to access one of the servers connected to the internet. Then, using a terminal program such as minicom, tip or cu, access the SERIMUX-CS-xx Console Switch. Log in to the SERIMUX-CS-xx Console Switch to access any of the serial management ports of the servers as shown below.
Connecting RJ45 Port on a NTI Console Serial
Switch to RJ45 Port on Digi PortServer II
Signal Flow Diagram
From Digi PortServer RJ-45
Signal
Direction
To NTI Console Switch RJ-45
1
DSR
DTR
7
2
RTS
CTS
3
Shield
Do Not Connect
4
TxD
RxD
6
GND
GxD
8
DCD
Connect a RJ45 port on a NTI Console Serial Switch SERIMUX-CS-x or SERIMUX-S-x to a RJ45 port on the Digi PortServer II to replace terminals. Using CAT5/5e/6 cable, arrange the wires in a RJ45 plug on each end to match the pinout for the corresponding port it will be connected to.
Console Serial Port Switches
Description
Power Cord Length
Price
Quote
Buy
4-port console serial port switch
265.00
4-port console serial port switch, Ethernet control
445.00
4-port console serial port switch, dual power
320.00
4-port console serial port switch, Ethernet control, dual power
500.00
8-port console serial port switch
385.00
8-port console serial port switch, Ethernet control
555.00
8-port console serial port switch, dual power
440.00
8-port console serial port switch, Ethernet control, dual power
610.00
16-port console serial port switch
490.00
16-port console serial port switch, Ethernet control
660.00
16-port console serial port switch, dual power
545.00
16-port console serial port switch, Ethernet control, dual power
715.00
24-port console serial port switch
640.00
24-port console serial port switch, Ethernet control
810.00
24-port console serial port switch, dual power
695.00
24-port console serial port switch, Ethernet control, dual power
865.00
32-port console serial port switch
755.00
32-port console serial port switch, Ethernet control
925.00
32-port console serial port switch, dual power
32-port console serial port switch, Ethernet control, dual power
980.00
DB25M-RJ45F-C
Adapt a modem to the SERIMUX
5.00
DB9F-RJ45F
Adapt DB-9M serial ports to the SERIMUX
DB25M-RJ45F-T
Adapt DB-25F serial ports to the SERIMUX
DB25F-RJ45F
Adapt DB-25M serial ports to the SERIMUX
RJ45MF-RS232-CO
Adapter to connect SUN/Cisco RJ45 serial ports to the SERIMUX
6.00.
UPCI 16-Port serial card is compatible with existing rackmount equipment. The industrial multi port serial card from COMTROL works in harsh environments.